Single/multi-lumen extension lines with uni/bidirectional valves
Octopus with Bionector (1-5 lumen)
Beskrivning
Protect-a-set (code 836.02) and Octopus 2 (other codes) are polyurethane, transparent, supple with low dead space double-lumen extension tubes for IV… Läs mer
Indikation
Octopus is an IV catheter accessory particularly recommended:
- to have more access ports in single-lumen CVCs used in neonates and infants,
- an extension line for short IV cannula in adults,
- in order to avoid the use of stopcocks or ramp of stopcocks ...
Produktens höjdpunkter
-
Infusion line management:
- 1 to 5 lumen
- Safety needleless connectors as a standard
- Versions with non-return valves
- Suitable for all kind of patients. Octopus with Bionector is particularly adapted for neonates thanks to the small design and the minimal dead space of the lines
-
Easy to use for the nurses:
- simple line assembly
- dedicated lines to better manage drugs incompatibilities
- limited handlings limiting the risk of error (vs stopcock)
Beskrivning
Protect-a-set (code 836.02) and Octopus 2 (other codes) are polyurethane, transparent, supple with low dead space double-lumen extension tubes for IV catheters (peripheral or central venous) fitted with one or 2 Bionector.To identify the different infusion lines, each line has a hub or a clamp of a different colour.
They allow to connect to the catheter several independant IV lines.
Code 841.232 is a double lumen extension tube with 2 non-return valves, 2 Bionector and 2 clamps (green).
Length of tubes: 3 cm / 3 cm.
Code 841.264 is a double lumen extension tube with 2 Bionector and 2 clamps (green and orange).
Length of tubes: 10 cm / 10 cm.
Code 842.209 is a double lumen extension tube with 1 non-return valve, 2 Bionector and 2 clamps (green and orange). The end without non-return valve allows the sampling blood.
Length of tubes: 6 cm / 6 cm
Used for peripheral cannula care, Octopus 2 has the following advantages:
- Eliminates the risk of access-associated needle-stick injury
- Reduces the risk of cannula movement in the vein causing mechanical vein irritation
- Negates the need to use the cannula injection port (non disinfectable), Bionector is disinfectable
- Eliminates the need to use a 3-way tap to run simultaneous compatible solutions
- Provides closed system (avoiding blood reflux) when accessing the catheter
- PUR material (no PVC, DEHP-free - no release of softeners)
Non-return valves avoid reflux of fluids or drugs beyond the valve during multiple infusions.
Bionector can be disinfected with most of the antiseptic solutions (example: 70% alcohol). Avoid using antiseptic containing both alcohol and hydrogen peroxide.
For more information about Bionector, please refer to technical file code 896.
Octopus with Bionector are also available with 1 lumen (code 5222.014), 3 lumen (codes 841.364-842.311/312), 4 lumen (code 842.414) and 5 lumen (code 842.514).
Referenser och funktioner
Extension tube | Lumen 1 | Lumen 2 | Förpackning | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Favourites | Kod | Total priming volume ml | Int. Ø mm | Ext. Ø mm | Priming volume (without non-return valve) ml | Length cm | Priming volume ( with non-return valve) ml | Flow rate (lumen with non return valve) ml/min | Flow rate (lumen without non return valve) ml/min | Prim. vol. ml | Flow rate ml/min | Flowrate ml/min | Length cm | Int. Ø mm | External diameter mm | Priming volume ml | Length cm | Int. Ø mm | External diameter mm | Priming volume ml | Flowrate ml/min | Antal/Avd.förpackning | Antal/Trp.förpackning |
841.232 | 0.50 | - | - | - | - | - | - | - | - | - | 78 | 3 | 1.50 | 2.50 | 0.30 | 3 | 1.50 | 2.50 | 0.30 | 78 | 10 | 240 | |
841.264 | 0.57 | - | - | - | - | - | - | - | - | - | 82 | 10 | 1.50 | 2.50 | 0.34 | 10 | 1.50 | 2.50 | 0.34 | 82 | 50 | 300 | |
841.364 | 0.81 | 1.50 (x3) | 2.50 (x3) | 0.34 (x3) | 10 (x3) | / | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 | 90 | |
842.209 | 0.58 | - | - | - | - | - | - | - | - | - | 73 | 6 | 1.50 | 2.50 | 0.36 | 6 | 1.50 | 2.50 | 0.33 | 78 | 10 | 240 | |
842.311 | 0.84 | 1.50 (x3) | 2.50 (x3) | 0.33 | 6 (x3) | 0.36 (x2) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 | 240 | |
842.312 | 0.89 | 1.50 (x3) | 2.50 (x3) | / | 6 (x3) | 0.37 (x3) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 50 | 300 | |
842.414 | 1.2 | 1.50 (x4) | 2.50 (x4) | 0.25 | 6 (x4) | 0.36 (x3) | 78 (x3) | 84 | - | - | - | - | - | - | - | - | - | - | - | - | 10 | 120 | |
842.514 | 1.1 | 1.50 (x5) | 2.50 (x5) | - | 6 (x5) | - | - | - | 0.25 (x5) | - | - | - | - | - | - | - | - | - | - | - | 10 | 120 | |
5222.014 | - | 1.50 | 2.50 | - | 10 | - | - | - | 0.29 | 75 | - | - | - | - | - | - | - | - | - | - | 50 | 300 |
Ytterligare information
-
Innehåller latex Nej
-
Innehåller animaliska produkter Nej
-
Pyrogenfri Ja
Dokumentation
-
Brochure Octopus Neonat
-
Bionector Product Range
-