Gastric tubes
Dual flow gastric tubes
Beskrivning
Dual flow gastric tube for continuous gastric aspiration with nutrisafe2 connection: Made of PVC The main channel is fitted with a removable… Läs mer
Indikation
Continuous gastric aspiration to empty stomach (air, secretions) before, during and after surgical intervention of an intubated patient or in case intestinal occlusion. This device can also be used for gastric lavage in case of bleeding.
Produktens höjdpunkter
In order to respond to the specific needs of neonatology, Vygon promotes an enteral range dedicated to neonates and newborns, called nutrisafe2. This range is compliant with ISO 80369-1.
Safe
Specially designed for neonatal patients, nutrisafe2 is a unique safe enteral feeding system incompatible with Luer and other small-bore connectors in accordance with ISO 80369-1 requirements. The risk of misconnection is minimized, and the patient safety is increased.
The lockable system provides additional security. Accidental disconnection is practically impossible, ensuring precious nutrients are received.
Clean
Feeding tube must not create extra risk to neonates by introducing bacteria into their digestive tract.
Studies have shown that the design of ENFit™ comes with the need of setting up a cleaning procedure, and that even followed thoroughly, only 31% of connectors were off residues. (1)
nutrisafe2 is, by design, less prompt to keep residues. Indeed, nutrisafe2 connectors have a less threaded interior to sequester milk or medication and is much smaller. (2)
(1) Lyman, B., Rahe, K. L., Keeler, D., Sherman, A. K., & Abdelhadi, R. A. (2020). Randomized Controlled Trial Assessing the Effectiveness of Two Cleaning Regimens for ENFit® Connectors. Medsurg Nursing, 29(6), 401-406
(2) Risks for Neonates Due to ENFitTM von Dr. Keliana O’Mara.; 2022. Accessed August 4, 2022.
Accurate
Dose accuracy is of great importance in the NICU wards, especially for critical drugs administration. For example, the morphine dose for a preterm baby can start at 0.03 ml. Studies have shown that because of fluid displacement there is an overdosing risk with the syringes.
Beskrivning
Dual flow gastric tube for continuous gastric aspiration with nutrisafe2 connection:- Made of PVC
- The main channel is fitted with a removable taper connector (code 368.12)
- The extension tube of the secondary channel ends with a male nutrisafe2 hub
- Closed distal tip with 6 lateral eyes
- Numerical markings every centimetre from 5cm to 45cm
- Radiopaque
- The product is also supplied with a straight double taper connector
- Length: 60cm
- Transparent to visualize the administered solution
Available in 6Fr (code 340.062) and 8Fr (code 340.082).
Referenser och funktioner
Tube | Förpackning | ||||
---|---|---|---|---|---|
Favourites | Kod | Diameter Fr | Length cm | Antal/Avd.förpackning | Antal/Trp.förpackning |
340.062 | 6 | 60 | 10 | 180 | |
340.082 | 8 | 60 | 10 | 180 |
Ytterligare information
-
Innehåller latex Nej
-
Innehåller animaliska produkter Nej
-
Pyrogenfri Nej
Dokumentation
-
Brochure Nutrisafe2
-
Enteral nutrition catalogue
-
FAQ - The new ISO standard for enteral nutrition ISO 80369-3
-
Instruktioner för användning